Strives to use all the latest achievements of technical progress in tonometers of the NISSEI brand.

 

Now pressure measurement with NISSEI brand blood pressure monitors has become even more comfortable and accurate.

img
img

High Resolution Scanning

Is a high accuracy pulse wave interval measurement system that acquires six times the volume of data during measurement compared with previous NISSEI products.
It facilitates better identification of the irregular intervals of pulse waves than ever before.

Models: WS-C2,
img

Abnormal pulse rhythm

When two symbols are indicated together, it means possibly higher degree of influence on the blood pressure measurement result due to the occurrence of severer abnormal pulse rhythm.

Models: WS-C2,
img

Pulse pressure measurement

A cardiovascular system performance index is calculated as a difference between systolic and diastolic pressures. Any pulse pressure level detected may adequately reflect the “real age” of arterial vessels that may agree by no means always with their “biologic age”. Knowledge of pulse pressure allows prevent such severe diseases, as blood-vascular organ and kidney pathologies, stroke and myocardial infarction at the very early stages.

img

Fuzzy inflation

This product employs automatic inflation pressure selection to ease stress on arm during cuff inflation. By detecting pulse signals while inflating, this product is able to determine the sufficient maximum inflation pressure for each measurement.

img

Measurement on inflation

Cuff inflation measurement algorithm for quick and comfort pressure and pulse rate.

Models: DSK-1011,
img

Body motion detection

When a noise indicator is displayed, measurement results shall be duplicated at rest and in silence, thus preventing any possible interference effects.

img

Сuff condition indicator

This device tests whether a cuff is fixed properly. When a cuff is fixed correctly, seats untight and unloosed, icon “OK” is displayed.

Models: DSK-1031,
img

Reliability indicator

Specific rules shall be followed to obtain exact final results – i.e. do not interfere in measurement process; make sure that a cuff is properly fixed; etc. This device automatically checks up environmental conditions and, if the above rules are observed, it displays a reliability icon.

Models: DSK-1031,
img

M-shaped cuff

A unique M-Cuff product is designed and patented by NISSEI. It reliably reads a pulse wave from two wrist arteries at once, thereby improving measurement accuracy results.

Models: WSK-1011,